Home>>AC Power Conditioner>>Telecom Specific Power Conditioner
Telecom Specific Power Conditioner


- Overview
- In telecom field, maintaining correct incoming supply voltage to equipment such as rectifiers and air condition units is necessary to avert malfunctions and to increase MTBF(Mean Time Between Failures) of the equipment. The cost of power conditioner compare to the purchase of telecom equipment and the subsequent loss of revenue due to failure is minimal. With MODERN’s several decades of experience of mains quality all over the world we now can present a power conditioner that meets the telecom sector’s stringent requirements: a reliable high performance product, long lifetime, and low maintenance. We have often noticed that in areas with large voltage variations there are often problems with the incoming neutral wire. The best way to reduce that neutral problem is simply not to use it! All our power conditioners can have a Delta/Wye isolation transformer option that allows the customer to avoid all problems caused by the neutral from the mains. Inside the power conditioner, a new clean neutral is then locally created, giving optimum working condition for the connected AC loads.
- Features and benefits
- •.Extremely wide voltage regulation range, 130-300 V line to neutral
- •.Three phase 400/230 V, capacity up to 2000KVA on request
- •.Small dimensions with integrated isolation transformer input
- •.Indoor and outdoor version on request
- •.Individual regulation for each phase
- •.Reliable and quiet servo motors
- •.Voltage meter
- •.By-Pass switch
- •.Very high capacity to handle large inrush currents(i.e. compressors)
- •.High efficiency-approx. 95 % at full load
- •.Wheels mounted for easy installation
- Applications
- •.2G, 3G, GSM and CDMA mobile base stations and control centers
- •.Outdoor shelters and cabinets
- •.Telecom exchanges/base stations needing outdoor power supply
- •.Medium exchanges, rural telecom networks and access networks
- •.Transmission relay stations
- •.Microwave/satellite communications stations
- •.Network control centers
- •.Emergency communications/transmission
- Technical Parameter
Input Voltage DBW SBW 220±15%,20%,30%,50% 380±15%,20%, 25%30%,50% Output Voltage
(Preset at 1.5%)220Vac±1-5% 380Vac±1-5% Efficiency >98% Precision 1-5% Frequency 47-53Hz Response Time <0.5S/20V(Line Voltage) Insulated Strength 2000V/1 minute without puncture 2500V/1 minute without puncture Insulated Resistance >2MΩ Wave Deformation Nil Isolation transformer Optional Surge Protection Optional - Model & Specifications
Phase Model Rated Capacity(KVA) Dimension(H×W×D)mm Cabinet(QTY) Single Phase DBW-10 10 1020×300×700 1 DBW-15 15 1020×300×700 1 DBW-20 20 1020×300×700 1 DBW-30 30 1020×300×700 1 DBW-50 50 1120×380×750 1 DBW-80 80 1220×400×780 1 DBW-100 100 1220×400×780 1 DBW-150 150 1420×450×930 1 DBW-200 200 1420×450×930 1 Three phase SBW-F10 10 1020×300×700 1 SBW-F20 20 1020×300×700 1 SBW-F30 30 1020×300×700 1 SBW-F50 50 1120×380×750 1 SBW-F80 80 1220×400×780 1 SBW-F100 100 1220×400×780 1 SBW-F150 150 1420×450×930 1 SBW-F200 200 1520×520×980 1 SBW-F300 300 1720×600×1380 1 SBW-F500 500 1860×720×1580 1 SBW-F800 800 1860×900×1080 1 SBW-F1000 1000 1860×900×1080 2 SBW-F1500 1500 1860×900×1080 3 SBW-F2000 2000 1860×900×1080 3